consumer unit busbar fitting

On a job today and in a consumer unit came across a split load board with usual cables from bottom of main switch to rcds. Some older systems such as those that use MK or old MEM Consumer Units that had one fuse per spur, so for instance: On this Wikipedia the language links are at the top of the page across from the article title. A garage consumer unit is used to feed up fewer load circuits (generally 2-5 units). This would, most often, leave you in the unnecessary position of having no lights or power. Consumer Unit Busbar - 20 Modules. Less common than the other types, an RCD incomer does not use a main switch. We Rely on Advertising to Help Fund Our Site and Provide Free Information. RCD+RCBO, How to Wire 230V Dual Split Load Consumer Unit? This generally applies to higher Amp rated appliances (showers, cookers etc) but it should always be checked with an electrician as to which circuits need to be placed on the RCD side of the consumer unit. It protects electrical appliances from damage and more importantly, human beings from electrical shock. Consumer Unit Busbar - 11 Modules. [email protected] How to Wire 120V & 240V Main Panel? endstream endobj startxref Download this stock image: Necar Zadegan visits the Pull-In showroom for a fitting Los Angeles California - D0N3EA from Alamy's library of millions of high resolution stock photos, illustrations and vectors. Vestibulum in blandit enim. This way, the light bulbs will still glow if a fault occurs on the three pin socket which will trip the desired MCB. RCD+RCBO, Wiring a Single-Phase Split Load Consumer Unit & Distribution Board : IEC, EU & UK, Split load consumer unit is the combination of, MCB = Overload and overcurrent Protection, RCD = Earth Fault Protection (to avoid electric shock), RCBO = MCB + RCD = Earth Fault + Overload and Overcurrent Protection. hbbd```b``6 i#dGA${0 a} ">` WDrEuAdv f.bc*":`Rl&XY,, fHm;A `3 RCDs have a test button which creates an earth leak with a resistor, and it is usually recommended that they are tested once a month. A dual RCD consumer unit can be fitted. Black for Neutral, Red for Phase or Hot and Green for earthing. This rule pretty much covers every single socket in the house so the ring main should be placed on the RCD protected side of the consumer unit. The load points and circuits on the RCD + MCB side can be connected via three wires i.e. An RCD is a manually operated isolator switch, but it is also an automatic safety device that will trip and cut off as soon as it senses an earth fault. Get Free Android App | Download Electrical Technology App Now! Be careful because its all about electricity and electricity is too dangerous. Wiring a Garage Consumer Unit with RCD & Connecting 1-, 230V Load Points in it. Wylex have no miss busbar connections and quick release technology built into their circuit breakers, RCBO's and AFDDs. Consumer Units . It is because split load consumer units provide protection against overload, overcurrent & short-circuit and earth leakage. Domestic busbars are simply plugged into the bottom of the relevant devices and secured into place. Grab your copy now for all the DIY help you need right at your finger tips! This type of consumer unit was very popular in Britain until 2001 when wiring regulations mandated residual current device (RCD) protection for sockets that could "reasonably be expected to" supply outdoor equipment (BS 7671:2001, .mw-parser-output cite.citation{font-style:inherit;word-wrap:break-word}.mw-parser-output .citation q{quotes:"\"""\"""'""'"}.mw-parser-output .citation:target{background-color:rgba(0,127,255,0.133)}.mw-parser-output .id-lock-free a,.mw-parser-output .citation .cs1-lock-free a{background:url("//upload.wikimedia.org/wikipedia/commons/6/65/Lock-green.svg")right 0.1em center/9px no-repeat}.mw-parser-output .id-lock-limited a,.mw-parser-output .id-lock-registration a,.mw-parser-output .citation .cs1-lock-limited a,.mw-parser-output .citation .cs1-lock-registration a{background:url("//upload.wikimedia.org/wikipedia/commons/d/d6/Lock-gray-alt-2.svg")right 0.1em center/9px no-repeat}.mw-parser-output .id-lock-subscription a,.mw-parser-output .citation .cs1-lock-subscription a{background:url("//upload.wikimedia.org/wikipedia/commons/a/aa/Lock-red-alt-2.svg")right 0.1em center/9px no-repeat}.mw-parser-output .cs1-ws-icon a{background:url("//upload.wikimedia.org/wikipedia/commons/4/4c/Wikisource-logo.svg")right 0.1em center/12px no-repeat}.mw-parser-output .cs1-code{color:inherit;background:inherit;border:none;padding:inherit}.mw-parser-output .cs1-hidden-error{display:none;color:#d33}.mw-parser-output .cs1-visible-error{color:#d33}.mw-parser-output .cs1-maint{display:none;color:#3a3;margin-left:0.3em}.mw-parser-output .cs1-format{font-size:95%}.mw-parser-output .cs1-kern-left{padding-left:0.2em}.mw-parser-output .cs1-kern-right{padding-right:0.2em}.mw-parser-output .citation .mw-selflink{font-weight:inherit}ISBN0-86341-373-0). The modern consumer unit is the centre, or heart, of the wiring system in the home. Although more expensive than a consumer unit with one or two RCDs and separate circuit breakers, RCBOs have the advantage that a fault will only affect a single circuit . You have done, the electrical appliances now can be connected to the new wired consumer unit and its MCBs via three wires i.e. Follow, Copyright 2023, All Rights Reserved 2012-2023 by, Looks Like You're Using an Ad Blocker. RCD+MCB, Wiring of the Distribution Board with RCD, Wiring of the Distribution Board without RCD, Single Phase Electrical Wiring Installation in Home NEC & IEC, Three Phase Electrical Wiring Installation in Home NEC & IEC, How to Wire a Three Phase, 400V Distribution Board? Check that all live prods on the devices are fully inserted and located into the live busbar. First of all, disconnect the Fuse between kWH energy meter and the utility pole to cut-off the main power supply. This unit has one main switch, two RCDs and each circuit has it's own MCB. An information label near the consumer unit explains this. A Garage Consumer is a type of consumer unit and distribution board (aka mini consumer unit) used to extend and provide electric supply to the exterior buildings such as shed, workshop or other outdoor installations in the garage. How to Determine the Number of Circuit Breakers in a Panel Board? Postage: 23.73Expedited Deliveryto United States via eBay's Global Shipping Programme. You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for \"GSH Electrical. RCD +MCB in a single unit. In the tutorials above, We have used the IEC wiring color codes (applicable to EU, UK and other countries) as follows. Read carefully all the cautions and instructions and follow them strictly while doing this tutorial or any other work in practical related to electrical works. We work with the industries best to ensure that we recommend only reliable and trustworthy tradesmen. Moreover, connect the output Phase wire from the main switch to the RCBOs via common busbar segment. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Enter Your Email Address to Subscribe to this Blog and Receive Notifications of New Posts by Email. Similarly, the 32A breaker can be used for electric ranges, electric showers and other high power devices. Now, connect the output Neutral wire from the main switch (as blue color) to the common Neutral Busbar terminal in the consumer unit. ), and how much protection is required for each circuit. This can also be an expensive solution as it necessarily uses, Dual RCD Consumer Unit - Offers a cost-effective solution to meet 17th Edition Regulations by protecting two banks of circuits from earth leakage through the use of two. Just wanted to check this is ok? Required fields are marked *. Notify me of follow-up comments by email. https://rover.ebay.com/rover/0/0/0?mpre=https://www.ebay.co.uk/ulk/itm/203078425782. fitting los necar . marketing, promotion, packaging, advertorials, and consumer or merchandising products. You can create your listing free at DIYnot Local. When it comes to what is now equivalent to imperial in terms of the new standard, this is now as follows: The image below shows the mains double pole isolating switch and an MCB clipped into place on the DIN bar.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'diydoctor_org_uk-leader-3','ezslot_15',811,'0','0'])};__ez_fad_position('div-gpt-ad-diydoctor_org_uk-leader-3-0');Consumer Unit with MCB and main double pole isolation switchif(typeof ez_ad_units!='undefined'){ez_ad_units.push([[580,400],'diydoctor_org_uk-large-leaderboard-2','ezslot_11',685,'0','0'])};__ez_fad_position('div-gpt-ad-diydoctor_org_uk-large-leaderboard-2-0'); Consumer Unit with MCB and main double pole isolation switch, The image below shows two MCBs and the bus bar. . Read carefully all the cautions and instructions and follow them strictly while doing this tutorial or any other work in practical related to electrical works. This will protect all circuits but if the RCD trips, so do all circuits. The first one for RCBOs common busbar and the second one for RCD and common busbar for associatedMCBs. Electric Bill Calculator with Examples, How to Find The Suitable Size of Cable & Wire for Electrical Wiring Installation? How to Determine the Right Size Capacity of a Subpanel? A garage fuse box is simple to install, troubleshoot and repair due to the simplicity and basic design with top hinged door. consumer unit busbar fitting. IEC, UK & EU, Wiring of the Distribution Board with RCD, Wiring of the Distribution Board without RCD, Single Phase Electrical Wiring Installation in Home NEC & IEC, Three Phase Electrical Wiring Installation in Home NEC & IEC, Single-Phase Electrical Wiring installation in a Multi-Story Building, 3-Phase & 1-Phase Electrical Distribution Wiring Installation in Multistory Building. Search stock photos by tags. endstream endobj 103 0 obj <> endobj 104 0 obj <>/ExtGState<>/Font<>/XObject<>>>/Rotate 0/StructParents 1/Type/Page>> endobj 105 0 obj <>stream Since the introduction of (BS 7671:2008 incorporating amendment no 1: 2011) 17th Edition IET Wiring Regulations, consumer units in the UK must provide RCD protection to all cables embedded in walls excepting high integrity circuits such as those for burglar alarms or smoke alarms. Contact the licensed electrician or the, The distribution board should not be installed 2.2 meter above the floor, must be protected from the corrosion and away from watery areas. Do not attempt removal or replacement unless you are you are qualified to Part P regulation standards. Generally a "split load" arrangement is used with some circuits protected by the RCD, and others not. Circuit-breaker on left-hand side incorrectly installed with busbar tang/ finger outside the termination clamp Be careful because its all about electricity and electricity is too dangerous. This unit has one main switch, two RCDs and each circuit has its own MCB. Similarly, connect the Phase or Live wire L (Brown color) to the live terminal of RCD. A look at RCBOs and how they are fitted into a typical consumer unit. 46.93 inc vat. 6181Y Easi-Fit Meter Tails Kit 25mm 3m. Import charges: Free amount confirmed at checkout. Cheers E ElectekAir Well-known member Joined Jul 3, 2008 Messages 449 Reaction score 0 Jul 11, 2012 #2 This protects all areas including showers and cookers, but if one trips the other will ensure at least some lights and some sockets still work. The use of RCDs is necessary, on two occasions, to meet the wiring regulations. I think it was either a loose connection or dust/dirt in the connection. The first one is a single load fuse board where the power coming in is taken through a double pole switch to a live bus bar. K5593S. If only a small amount of load points are needed to power up through mains supply, they install a garage consumer unit instead of larger consumer units especially in outbuildings. K5511S. The split board shown here has one RCD and is a simple version to show the user how the board works. k'(Pr} DtD&}C{u*3Ym,dzWHo+H9wKCf.}tOGn1>P|p[}1s`91bLldsi_>-NM2'fiHKYw4+\Gl{(A,?zC "G>E a^ Left one may be correct, but it's too short, the red loop of wire is not acceptable. While the socket outlet and washing machine has been fully protected by RCBO i.e. 112 0 obj <> endobj How to fit a miniature circuit breaker (MCB) or RCBO to a busbar in a consumer unit (fuse box). All images used on this website are subject to copyright Luceco plc and other image rights holders where applicable. A consumer unit can use an RCD as the main switch. Design 10 Design 10 is our board for all applications. In addition, for arc fault protection (mentioned first time in the the IET Wiring Regulations 18th edition BS 7671: 2018, AFDD (Arc Fault Detection Device) is the term used in the UK while it is known as AFCI (Arc Fault Circuit Interrupter) in the US. Includes international tracking. You simply plug the electronic component into the bottom of your circuit board and secure it in place. The case is a little bit different in case of RCBOs as follows. To connect the rated MCBs and RCD in the garage consumer unit for specific appliances, follow the following simple steps. Phase, Neutral and Protective Earth. When the MCBs are clipped onto the DIN bar, the bus bar is inserted into the live terminal at the bottom of the MCB. Environmental and energysaving LED lighting, Interior and exteriorportable power solutions, Audio visual andhome entertainment products, UK Customer Services: +44 (0)1952 238 100. These cables are called tails, and in this instance, with this type of unit, are 16mm cables. Delivery: Estimated between Fri, 17 Mar and Wed, 22 Mar to 23917. The author will not be liable for any losses, injuries, or damages from the display or use of this information or if you try any circuit in wrong format. 22.13 inc vat. Phase from single pole MCB, Neutral from Neutral busbar and Earth wire from the. HAG VML110. if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'diydoctor_org_uk-box-3','ezslot_4',822,'0','0'])};__ez_fad_position('div-gpt-ad-diydoctor_org_uk-box-3-0');Warning: To complete electrical works you must comply with Electrical Regulations. endstream endobj startxref As they must sense the current in both the line and neutral, they have connections for both. Brown as Live L, Blue as Neutral N and Protective Earth E as Green with Yellow Stripe. [2], Some manufacturers have added innovative features such as CPN Cudis who have added a LED strip light to their 'Lumo' consumer unit to enhance visibility in dark locations such as under staircases.[3]. (ex. These boxes can also be fitted with cartridge fuses or miniature circuit breakers (MCBs). There are a number of different ratings for current and sensitivities to current leakage available, so you will need to understand which are the appropriate ratings for your home. Where the cranked one isnt in the rcd. . Search stock photos by tags. If you need to find a tradesperson to get your job done, please try our local search below, Im more worried about the one on the right. No you cant use other brands with the exception of Crabtree ones that look the same. The choice of consumer unit will reflect several factors such as the size and layout of the dwelling, number of floors, outbuildings, the expected load levels (ovens, showers, immersion heaters, electric . All cables and connections to the consumer unit must be checked and tested by a qualified electrician. This will vary and you should always check with a qualified electrician.Main double pole isolation switch on din bar with live and neutral coming into the main double pole switch from the meter and earth terminal block, Main double pole isolation switch on din bar with live and neutral coming into the main double pole switch from the meter and earth terminal block. Examples in Imperial & Metric System, Working of Electric Mosquito Killer Racket / Fly Swatter Bat. The output N terminal of RCD should be connected to the Neutral busbar terminal in the consumer unit. It may be used, for example, with a main switch board when mounting an RCD. This way, the protection to the load points are as follows. The CU never tripped and it and the MCB's are not overloaded. How to Wire 120V Water Heater Thermostat Non-Simultaneous? A smaller white lead is a functional earth connection. In addition, connect the RCD to the output phase wire of the main switch through jumper wire(as brown color). Product Information Lockable covers are pre-assembled Ideal during first installation to ensure power isolation, and protect installer Barrel Lock included Direct replacement for standard cover For use with BG Fortress Consumer Units New up opening front cover Suitable for restricted space areas due to compact size Downloads You must log in or register to reply here. Whilst each installation requires individual design and set up there are highly standardised and regulated approaches to configuration. When screwed tight this gives live feed to all the MCBs.Consumer Unit with MCBs and Bus Bar. Split load consumer unit is the combination of RCBO Residual Current Breaker with Over-Current, RCD Residual Current Device and MCB Miniature Circuit Breaker. RCDs also work by detecting an imbalance between the Live and the Neutral conductors and this feature is a requirement for all Class 2 double insulated equipment. The top mounted terminal rail makes the wiring of the neutral and earth connections neat and simple. Wylex have no miss busbar connections and quick release technology built into their circuit. K5590S. marketing, promotion, packaging, advertorials, and consumer or merchandising products. Barrel Lock And Key Set - Suitable For Locking Sentry Consumer Unit Lids. It may not display this or other websites correctly. Home > DIY How To Projects and Tutorial Guides > Installing a Consumer Unit Consumer Units Explained. Select the supplier or trade you require, enter your location to begin your search. For example, the LED lamp and ceiling fan is controlled and protected by RCD + MCBs. The resistor passes more current than that required for tripping, and the duration of the test is not limited, so testing in this way does not provide proof that the unit is working to specification. Corridor Wiring Circuit Diagram Hallway Wiring using 2-Way Switches, Tunnel Wiring Circuit Diagram for Light Control using Switches, Hospital Wiring Circuit for Light Control using Switches, Hotel Wiring Circuit Bell Indicator Circuit for Hotelling, Hostel Wiring Circuit Diagram and Working, Godown Wiring Diagram Tunnel Wiring Circuit and Working. For example, the LED lamp and, LED lamp & ceiling fan are protected by Main Switch => RCD => Single Pole MCB, Ceiling Fan & Socket Outlet Protected by Main Switch => RCBO = (RCD + MCB), IEC Wiring Color Codes 1-, 230V UK & EU. Mauris laoreet vulputate mauris. 102 0 obj <> endobj All the. There are two built-in wires namely FE Functional Earth as white colored wire and N Neutral as blue colored wire. Advice on installing a consumer unit. June 10, 2022 5:48 PM PT. 0 We will be using the IEC wiring color codes which is also applicable to EU, UK and other countries. Right busbar is fitted incorrectly - the label end should fit into the RCD, however it's not just a case of turning it round, because it's either the wrong bar, or someone has assembled the consumer unit incorrectly. A garage consumer unit is used to feed up fewer load circuits (generally 2-5 units). This way, a single phase load circuit is connected through three wires viz Phase, Neutral and Earth wire. As with all models in the range, there is ample cable space available even when RCBOs are fitted. This saves you the expense of replacing the entire board when you need to reconfigure electrical circuits. In the above case, you may connect the lighting points to the 6A MCB while the dual socket (for immersion heaters or dedicated freezer circuits) to the 16A MCB. To control the ON/OFF operation of the electrical appliances, an SP or DP switchescan be used in the sub circuits and final sub circuits. There are two additional Neutral busbars in the consumer unit viz for RCBOs and RCDs (for simplification and illustration). Please see our project on Part P of the building regulations for information on DIY Electrical Installation. You are using an out of date browser. Thus, the electrical bus bar collects the electric power at one location. *N1i5>/d'0I]f]WY`FX3 o<0`CRw/q!9G*0ZR/pu^lvX5V&`2^G". Ashley consumer units, anuone got any breakers. An RCBO consumer unit has one main switch but each circuit is protected by an RCBO which is a combination of an MCB and an RCD. The garage consumer unit would then just have a mains switch and MCBs for each circuit. It is also an offence to interfere with the seals on the electricity meter. Additionally, connect the single pole MCB to RCD through a common busbar segment as shown in fig. A consumer unit is a type of distribution board (a component of an electrical power system within which an electrical power feed provides supply to subsidiary circuits). IEC & UK. 158 0 obj <>stream Don't fancy doing this project yourself? The split load consumer unit is a safest panel box as compared to simple main switch, simple RCD type consumer unit or dual RCDs consumer unit. The split load consumer unit is a safest panel box as compared to simple main switch, simple RCD type consumer unit or dual RCD's consumer unit. Although more expensive than a consumer unit with one or two RCDs and separate circuit breakers, RCBOs have the advantage that a fault will only affect a single circuit. EE-Tools, Instruments, Devices, Components & Measurements, Split Load Consumer Unit Wiring Old UK Wiring Color Codes, Wiring 230V Single Phase Circuits in a Split Load Consumer Unit, differences between MCB, MCCB, ELCB & RCB, RCD or RCCB/RCBO Circuit Breakers, How to Wire Single-Phase, 230V Consumer Unit with RCD? Starbreaker consumer units are available as factory built units or for on site assembly in How to Wire and Install an Electrical Outlet Receptacle? If not applicable, Please follow the local area codes or general practiced color codes related to specific regions. We have used the followingIEC wiring color codes for 230V single phase supply voltage applicable in the UK and EU. A Split Load Consumer Unit is also known as High Integrity Consumer Unit which contains both RCDs and RCBOs. no need to connect the Neutral wire from the main neutral terminal in the consumer unit. IEC Wiring Color Codes for 230V, 1-Phase, 3-Wire System: EU & UK, Old UK Wiring Color Codes for Single Phase, 230V AC, Your email address will not be published. A garage fuse box is simple to install, troubleshoot and repair due to the simplicity and basic design with top hinged door. This can be done in 3 ways. Disconnect the power supply (and make sure it is really switched OFF) before servicing, repairing or installing electrical equipment. I have installed a new mcb in my consumer unit. Never stand or touch wet and metal parts while repairing or installation. 137 0 obj <>/Encrypt 113 0 R/Filter/FlateDecode/ID[<73D037194761440D82A4DB3A31246358>]/Index[112 47]/Info 111 0 R/Length 121/Prev 631834/Root 114 0 R/Size 159/Type/XRef/W[1 3 1]>>stream document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Enter Your Email Address to Subscribe to this Blog and Receive Notifications of New Posts by Email. So please! Moreover, you may use RCBOs with RCD instead of single pole MCB if needed. It's easy to connect your consumer unit to an isolation device with this Busbar 10 Module. This example has a flying lead for the incoming neutral connection and a standard terminal for the line busbar. Installation Instructions . There were a number of similar designs from other manufacturers but the Wylex ones are by far the most commonly encountered and the only ones for which fuseholders/breakers are still commonly available. Even More Electrical Wiring Installation & Tutorials, A Complete Guide About Solar Panel Installation. The choice of consumer unit will reflect several factors such as the size and layout of the dwelling, number of floors, outbuildings, the expected load levels (ovens, showers, immersion heaters, electric blankets, car-chargers etc. Nullam ultricies malesuada dignissim. Batten Fittings Site Lighting Bathroom Lighting Lamps & Tubes LED Compact Fluorescent LED Compact Fluorescent Motion Detectors Lighting Accessories Sockets, Switches & Data Switches & Sockets Zahler Square Edge Pearl Slimline Brushed Chrome Black Nickel Antique Brass Metal Clad Connect Grid Modules Euro Modules & Accessories In single phase supply, the voltage between phase and neutral is 230V AC. Hager VML110 10 Way RCBO Consumer Unit. In the image below, we show the earth cable from the meter (L). This item is commonly used in both residential and commercial settings including garages, outhouses and stables. In addition, for arc fault protection (mentioned first time in the the IET Wiring Regulations 18th edition BS 7671: 2018, The load points and circuits on the RCD + MCB side can be connected via three wires i.e. %%EOF Definition: An electrical bus bar is defined as a conductor or a group of conductor used for collecting electric power from the incoming feeders and distributes them to the outgoing feeders.In other words, it is a type of electrical junction in which all the incoming and outgoing electrical current meets. As this option is expensive it is only usually used where space is tight for the enlargement of a consumer unit as has to happen when updating to a dual RCD unit. 163 0 obj <>stream The FE should be connected to the main earth terminal block while the N as neutral should be connected to the main neutral terminal. In this tutorial, we will be showing how to install a single phase garage consumer unit for 230V with RCDs according to IEC. fitting los necar zadegan pull-in showroom . MCB Retro-Fit Kit - For Use When Installing MCBs Into Old Sentry Consumer Units With Fork Style Busbar. The protection devices in a split load CU do the following jobs. illinois obituaries 2020 . Calculator, How to Calculate the Battery Charging Time & Battery Charging Current Example, Automatic UPS / Inverter Wiring & Connection Diagram to the Home, How To Calculate Your Electricity Bill. In this case it is a 2.5mm cable for the ring main.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'diydoctor_org_uk-leader-4','ezslot_16',812,'0','0'])};__ez_fad_position('div-gpt-ad-diydoctor_org_uk-leader-4-0'); The live (O) is fixed into the top of an MCB on the RCD side of the unit, while the neutral (M) goes to the RCD neutral terminal block. no need to connect the Neutral wire from the main neutral terminal in the consumer unit. Instructions on wiring a consumer unit to UK specifications for dual RCD and RCBO consumer units. See details. . The cosumer unit did not have any spare busbar so I used a piece of 6mm insulated cable to link the last mcb with the busbar in to the new mcb. How to Wire 240V, 208V & 120V, 1 & 3-Phase, High Leg Delta Main Panel? Consumer Unit Recessed Kits Data Sheet (.pdf), 8 Module, cover complete with fitted visor and lock, 12 Module, cover complete with fitted visor and lock, 16 Module, cover complete with fitted visor and lock, 19 Module, cover complete with fitted visor and lock, 22 Module, cover complete with fitted visor and lock, Grey Plastic Gland Kit for 1-1.5mm flat cable c/w Flat cable insert, Locknut, Grey Plastic Gland Kit for 2.5-4mm flat cable c/w Flat cable insert, Locknut, Grey Plastic Gland Kit for 2x2.5mm flat cable c/w Flat cable insert, Locknut, Grey Plastic Gland Kit for 6mm flat cable c/w Flat cable insert, Locknut, Adaptor, Grey Plastic Gland Kit for 10-16mm flat cable c/w Flat cable insert, Locknut, Grey Plastic Tails Kit c/w Multiple Inserts, Locknut, Blanking Insert, Grey Plastic Tails Kit c/w Multiple Inserts, Locknut, Blanking Insert, Adaptor, Brass Gland Kit for 1-1.5 flat cable c/w Flat Cable Insert, Locknut, Brass Gland Kit for 1-1.5mm flat cable c/w Flat cable insert, Locknut, Brass Gland Kit for 2x2.5mm flat cable c/w Flat cable insert, Locknut, Brass Gland Kit for 2.5-4mm flat cable c/w Flat cable insert, Locknut, Brass Gland Kit for 10-16mm flat cable c/w Flat cable insert, Locknut, Brass Tails Kit c/w Multiple Inserts, Locknut, Blanking Insert, Brass Tails Kit c/w Adaptor, Multiple Inserts, Locknut, Blanking Insert, Grey Plastic Tails Kit, c/w Multiple Inserts, Locknut, Blanking Insert, Brass Tails Kit, c/w Multiple Inserts, Locknut, Blanking Insert, Consumer Unit Cover Blanks (pack of 10, 5 x pairs), Cable Kit includes neutral and live cables, terminal bar, fixing clip and spare labels (may be used to convert mains switch to split load consumer unit), Cover Lock (to suit all BG Consumer Units which are fitted with a lockable cover), Metal cover lock blank for use with the metal lockable covers after the barrel lock is removed, Ideal during first installation to ensure power isolation, and protect installer, Suitable for restricted space areas due to compact size, Supplied with adjustable brackets and trim, Adjustable brackets enable the consumer unit to be recessed between 42mm and 62mm from the outer surface of the wall, Enables 16 module consumer unit to be recessed into wall, Enables 19 module consumer unit to be recessed into wall, Enables 20 module consumer unit to be recessed into wall, Both Plastic and Brass Glands acceptable due to no set regualtion on cable entry, Tails Glands allow 2 x tails and 1 x earth cable to enter single entry whilst being individually sealed, All glands and grommets satisy IP4X (Maxiumum requirement as per NICEIC guideline sfor all cable entry and exit on horizontal planes), Cable retention negates requirement for additional tails clamp.